Data Center Multi-circuit Energy Monitoring Solution
10 Sep 2026
DATA CENTER POWER MONITORING
AMC100 Series Multi-circuit Energy Meter for Precision Power Distribution

The Acrel AMC100 series data center energy meter delivers high-density multi-loop acquisition for AC and DC distribution cabinets — covering main incoming and every outgoing PDU circuit, with local HMI display, multi-level alarm, and direct Modbus-RTU / Modbus-TCP / SNMP integration with third-party DCIM platforms.

Acrel AMC100 multi-circuit energy meter for data center
48
OUTGOING CIRCUITS
2nd-63rd
HARMONIC ANALYSIS
Modbus
RTU / TCP · SNMP
CE · IEC
CERTIFICATION
PRODUCT OVERVIEW
Precision Sub-metering for Every Circuit in Your Data Center

The AMC100 multi-circuit energy meter is purpose-built for data center power distribution — monitoring AC and DC main incoming circuits as well as high-density outgoing PDU and server rack loads. It is the essential instrument for branch-level energy metering and PUE calculation.

Dual A+B Incoming Monitoring
Independent measurement of redundant incoming circuits for full visibility of your power-supply architecture.
Branch-level PUE Calculation
Granular energy data from every outgoing circuit enables accurate PUE tracking and energy-efficiency optimization.
DCIM / BMS Ready
Standard Modbus-RTU, Modbus-TCP and SNMP output connects directly to your existing monitoring system.
Data center distribution cabinet with AMC100 energy meter
SYSTEM POSITION
Acrel Covers the Entire Power Chain

Acrel provides complete monitoring from 110kV substation down to IT racks. This page focuses on AMC100 energy monitoring at the precision distribution layer. Click any stage to explore its solution.

01
HV / MV Substation
110kV · 10kV
AM6 Protection Relay
→
02
MV Switchgear
10kV Distribution
ATE400 · APD300
→
03
LV Distribution
0.4kV Switchboard
ARTU · ATE400
→
NOW
Precision Distribution
Column-Head · PDU
AMC100 Meter
→
05
IT Server Racks
PDU · IT Loads
Energy Data to DCIM
CORE FEATURES
Engineered for Data-Center Grade Reliability
01
Dual-Circuit Incoming

AMC100-ZA for AC, AMC100-ZD for DC (-48V / 240V / 360V). Independent A+B main incoming monitoring with full electrical parameters.

02
High-Density Multi-loop

Up to 48 single-phase AC or 48 DC outgoing circuits in one DIN-rail module. Track every PDU and server rack branch.

03
Open Protocol

Modbus-RTU / Modbus-TCP / SNMP with 3-way RS485 and optional Ethernet. Plug-and-play with any DCIM, BMS or SCADA.

04
Multi-Level Alarm

Configurable thresholds for over-current, over-voltage and communication faults. DI for breaker status, DO relay output.

05
Harmonic Analysis

2nd to 63rd harmonic measurement protects sensitive IT equipment from harmonic distortion and power quality issues.

06
Local HMI Display

ATP007kT 7-inch touch screen provides real-time data, trends and alarm logs. Local visualization without upper platform.

07
CE & IEC Certified

Wide operating temperature range and robust EMC performance for 24/7 mission-critical data center operation.

08
Fast Installation

DIN-rail 35mm mounting with solid-core CTs or Hall-effect sensors. Retrofit existing cabinets without shutdown.

09
New & Retrofit Ready

Equally suited to greenfield data center projects and brownfield cabinet retrofits. Compact and flexible.

APPLICATION SCENARIOS
Where the AMC100 Delivers Value
01
AC Precision Distribution
Dual A+B incoming monitoring for AC cabinets — full visibility into every PDU branch.
02
DC Distribution
AMC100-ZD with Hall-effect sensors for DC metering at -48V, 240V and 360V bus systems.
03
Smart Busway & Plug-in Box
Monitor busway plug-in boxes and intelligent busbar systems — modern column-head alternative.
04
Server Rack PDU Monitoring
Per-circuit energy data for power billing, utilization analysis and load balancing.
05
DCIM / BMS Integration
Seamless Modbus-RTU/TCP and SNMP upload to third-party platforms.
06
Cabinet Retrofit Projects
DIN-rail modules and compact CTs enable fast, low-cost upgrades.
SYSTEM ARCHITECTURE
End-to-End Monitoring Chain
From Sensor to Upper-Level Platform

A complete data center power monitoring architecture in four layers.

01
Sensing Layer
AKH-0.66/W-9 CTs for AC, AHKC Hall-effect sensors for DC, on every monitored branch.
02
Acquisition Layer
AMC100-ZA/ZD main incoming + AMC100-FAK/FDK outgoing modules, DIN-rail mounted.
03
Display Layer
ATP007kT touch-screen HMI for local display, alarm configuration and data review.
04
Upload Layer
Optional Anet gateway. RS485 Modbus-RTU, Ethernet Modbus-TCP or SNMP to DCIM / SCADA.
Communication: RS485 Modbus-RTU, Ethernet Modbus-TCP, and SNMP — connects directly to customer's existing monitoring system.
Data center precision distribution cabinet with AMC100
SOLUTION OPTIONS
Pick Your Configuration

One architecture, two power types. Click any model to view full specifications.

COMPONENT AC DATA-CENTER SOLUTION DC DATA-CENTER SOLUTION
Main Incoming AMC100-ZA
2-channel 3-phase AC meter
AMC100-ZD
2-channel DC · -48V / 240V / 360V
Outgoing Circuits AMC100-FAK30 / FAK48
up to 48-ch single-phase AC
AMC100-FDK series
up to 48-ch DC outgoing
Current Sensing AKH-0.66/W-9A/B
solid-core current transformer
AHKC series
Hall-effect current sensor
Local Display ATP007kT
7-inch touch-screen HMI
ATP007kT
7-inch touch-screen HMI
Data Upload Anet Gateway
optional · Modbus-RTU/TCP · SNMP
Anet Gateway
optional · Modbus-RTU/TCP · SNMP
Optional — Insulation monitoring
DC bus ground resistance

Both configurations share the same HMI, protocols and DCIM integration — only the sensing layer differs.

PRODUCT SELECTION
Complete Product Lineup
AMC100-ZA AC main incoming energy meter
AMC100-ZA AC Main-Incoming
— 2 circuits 3-phase AC incoming
— 3-way RS485, optional Ethernet
— Harmonic 2nd-63rd, DI/DO
— DIN 35mm, CE / IEC
AMC100-ZD DC main incoming energy meter
AMC100-ZD DC Main-Incoming
— Dual-channel DC (-48V/240V/360V)
— 3-way RS485 communication
— DI/DO for status & alarm
— DIN-rail mounting
AMC100-FAK30 AC outgoing energy meter
AMC100-FAK30 AC Outgoing
— Max 30-ch single-phase outgoing
— Or 10-ch 3-phase outgoing
— Paired with AKH-0.66/W-9 CT
— RS485 Modbus-RTU
AMC100-FAK48 AC outgoing energy meter
AMC100-FAK48 AC Outgoing
— Max 48-ch single-phase AC outgoing
— High-density for large PDU loads
— Compact DIN-rail design
— RS485 Modbus-RTU
AMC100-FDK48 DC outgoing energy meter
AMC100-FDK48 DC Outgoing
— Up to 48 DC outgoing circuits
— For DC distribution (-48V/240V/360V)
— Works with AHKC series sensor
— RS485 Modbus-RTU
ATP007kT touch screen HMI
ATP007kT Touch-Screen HMI
— 7-inch local centralized display
— Multi-level alarm & buzzer
— 2-port RS485 + Ethernet
— Data forwarding to DCIM
SITE INSTALLATION
Deployed in Real Data Centers
On-site installation of AMC100 in data center
AMC100 wiring on-site installation
AMC100 energy meter on customer site
Column head cabinet row in data center
Intelligent PDC cabinet with AMC100
PDU interior with energy meter
Rack mount PDU in server room
Distribution cabinet with AMC100 installed
Need a Data Center Monitoring Solution?

Get technical datasheets, quotations and customized solution support. Our specialist responds within 24 hours.