The Acrel AMC100 series data center energy meter delivers high-density multi-loop acquisition for AC and DC distribution cabinets — covering main incoming and every outgoing PDU circuit, with local HMI display, multi-level alarm, and direct Modbus-RTU / Modbus-TCP / SNMP integration with third-party DCIM platforms.
The AMC100 multi-circuit energy meter is purpose-built for data center power distribution — monitoring AC and DC main incoming circuits as well as high-density outgoing PDU and server rack loads. It is the essential instrument for branch-level energy metering and PUE calculation.
Acrel provides complete monitoring from 110kV substation down to IT racks. This page focuses on AMC100 energy monitoring at the precision distribution layer. Click any stage to explore its solution.
AMC100-ZA for AC, AMC100-ZD for DC (-48V / 240V / 360V). Independent A+B main incoming monitoring with full electrical parameters.
Up to 48 single-phase AC or 48 DC outgoing circuits in one DIN-rail module. Track every PDU and server rack branch.
Modbus-RTU / Modbus-TCP / SNMP with 3-way RS485 and optional Ethernet. Plug-and-play with any DCIM, BMS or SCADA.
Configurable thresholds for over-current, over-voltage and communication faults. DI for breaker status, DO relay output.
2nd to 63rd harmonic measurement protects sensitive IT equipment from harmonic distortion and power quality issues.
ATP007kT 7-inch touch screen provides real-time data, trends and alarm logs. Local visualization without upper platform.
Wide operating temperature range and robust EMC performance for 24/7 mission-critical data center operation.
DIN-rail 35mm mounting with solid-core CTs or Hall-effect sensors. Retrofit existing cabinets without shutdown.
Equally suited to greenfield data center projects and brownfield cabinet retrofits. Compact and flexible.
A complete data center power monitoring architecture in four layers.
One architecture, two power types. Click any model to view full specifications.
up to 48-ch single-phase AC AMC100-FDK series
up to 48-ch DC outgoing
solid-core current transformer AHKC series
Hall-effect current sensor
optional · Modbus-RTU/TCP · SNMP Anet Gateway
optional · Modbus-RTU/TCP · SNMP
Both configurations share the same HMI, protocols and DCIM integration — only the sensing layer differs.
— 3-way RS485, optional Ethernet
— Harmonic 2nd-63rd, DI/DO
— DIN 35mm, CE / IEC
— 3-way RS485 communication
— DI/DO for status & alarm
— DIN-rail mounting
— Or 10-ch 3-phase outgoing
— Paired with AKH-0.66/W-9 CT
— RS485 Modbus-RTU
— High-density for large PDU loads
— Compact DIN-rail design
— RS485 Modbus-RTU
— For DC distribution (-48V/240V/360V)
— Works with AHKC series sensor
— RS485 Modbus-RTU
— Multi-level alarm & buzzer
— 2-port RS485 + Ethernet
— Data forwarding to DCIM
Get technical datasheets, quotations and customized solution support. Our specialist responds within 24 hours.