● Type: Smart Motor Protector
● Function:Phase loss,overload,locked rotor,blockage,three phase unbalance protection,etc.
● Measurement:Active kWh (positive and negative),quadrant reactive power energy.
● Electrical measurement: U、I、 P、Q、S、PF、F、THDv、Harmonic on 2nd-31st,etc
● Communication:RS485, WIFI
● Protocol:Modbus-Rtu,MQTT
● Installation:Separated type or integrated

The ARD3M series intelligent motor protector (hereinafter referred to as the protector) is suitable for low-voltage motor circuits with rated voltage up to 660V and integrates protection,measurement, control,communication, operation and maintenance.
■ The power module supports the power range of AC/DC100-415V.
■ Support fundamental wave and full wave power parameter measurement (U, I, P, Q, S, PF, F, EP, EQ), voltage and current unevenness Balance, voltage, current positive sequence, negative sequence, zero sequence components, three-phase voltage phase angle, residual current, voltage, current 2-63 times Sub-harmonic measurement, sub-harmonic content rate and total harmonic distortion rate.
■ Protection functions include overload inverse time limit, overload definite time limit, grounding, starting overtime, leakage, underload, phase failure, blockage Turn, block, short circuit, overflow, unbalance (current, voltage), over power, under power, over voltage, under voltage, phase sequence, temperature degree, tE time, external fault, limit of starting times, running time alarm, fault times alarm.
■ 10 programmable DI inputs, the default is built-in DC24V power supply, and external active wet contacts can also be selected
■ 6-channel programmable DO output, which can meet the requirements of direct starting, star-delta starting, autotransformer starting, etc.
The remote control "start/stop" of the motor from the master station can be realized through the communication bus.
■ Optional anti-shock function: support immediate restart after shock and restart after loss of pressure.
■ Standard 2-way MODBUS_RTU communication, there are PROFIBUS DPV1, Ethernet, PROFINET communication modules for Optional.
■ Optional 2-way DC4-20mA analog output interface, connected with the DCS system, can monitor the field equipment.
■ It has various event records such as fault record, start record, stop record, DI displacement record and restart record, which can be checked View a number of motor operation and maintenance information, and at the same time record the motor running record for 1-5 hours.
■ The display interface supports Chinese/English display.
■ Support U disk to export waveform record and event record data, you can use EXCEL to open and export event record file.
■ WIFI function can be added when the color LCD display is selected, and the WIFI can be connected to the mobile phone or computer to view and set the motor protection.
Its perfect protection function ensures the safe operation of the motor, with logic programmable function, can meet a variety of control methods.Different communication modules can be selected to meet the needs of field communication.

Protection Function
- Fixed time overload
- Inverse time overload
- Starting timeout
- Phase loss
- Voltage unbalance
- Current unbalance
- Locked-rotor
- under load
- Block
- Temperature protection(PTC/NTC)
- Residual current(grounding/leakage)
- Under voltage
- Over voltage
- Under power
- Over power
- tE Time protect
- Overflow protection
- Alarm of starting times
- Running time alarm
- Fault frequency alarm
Control Mode
- Protect type
- Manual mode
- Two step model
- Double speed mode
- Star triangle three successive
- Power Shake and start again
Communication function
- 2 channels Modbus-RTU communication
- 1-2channel PROFIBUS DPV1 communication
- 1channel PROFINET communication
- 1-channel Ethernet communication (dual network port)
- WIFI Communication











Company | Acrel | Schneider | Siemens | ABB | ||
Series | ARD2M | ARD3M | Tesys T | simocode pro V | UMC100 | |
measuring | current, heat capacity | √ | √ | √ | √ | √ |
Voltage, active power, active energy, frequency | √ | √ | √ | √ | √ | |
reactive power, reactive energy | √ | √ | √ | × | × | |
harmonic | 2-21th | 2-63th | × | × | total harmonics | |
Leakage current/ground current | √ | √ | √ | √ | √ | |
Positive sequence, negative sequence, zero sequence voltage, current | √ | √ | × | × | √ | |
PTC/NTC | √ | √ | √ | √ | √ | |
PT100 temperature measurement | √ | × | × | √ | External Module 6 ways | |
4-20ma input | × | × | × | External Module,2 ways | External Module 6 ways | |
Protection | Conventional current protection such as inverse time overload | √ | √ | √ | √ | √ |
overflow/quick break | √ | √ | × | × | √ | |
tE | √ | √ | × | × | √ | |
Voltage Dependent Protection | √ | √ | √ | √ | √ | |
leakage current | √ | √ | √ | √ | √ | |
temperature protection | √ | √ | √ | √ | √ | |
Insulation monitoring | × | √ | √ | × | × | |
Number of starts | √ | √ | √ | √ | √ | |
Event Record | Fault record | 8 | 8 | × | √ | 16 |
Start/stop record | 8 | 8 | × | × | ||
restart recording | 8 | 8 | × | × | ||
Displacement record | 8 | 8 | × | × | ||
fault recorder | × | 49 | × | × | ||
Power-on/power-off record | 8 | 8 | × | × | ||
running record | × | 5 hour | × | × | ||
Control | DI | 8 | 10 | 6(10) | 4(12) | 6(14) |
DO | 5 | 6 | 4 | 3(7) | 4(9) | |
start control | √ | √ | √ | √ | √ | |
Loss of pressure restart | √ | √ | × | × | × | |
4-20mA output | 1 | 2 | × | 1 | 1 | |
Graphical programming | × | × | √ | √ | √ | |
communication | Modbus-rtu | 2 | 2 | 1 | × | 1 |
Profibus-dp | 1 | 2 | 1 | √ | 1 | |
Profinet | × | 1(2 ports) | × | √2 ports | 1 (2 ports) | |
ModbusTCP | × | 1(2 ports) | 1 | × | 1 (2 ports) | |
Ethernet/IP | × | × | × | × | 1 | |
Devicenet | × | × | 1 (2 ports) | × | 1 (2 ports) | |
Profisafe | × | × | × | √ | × | |
can | × | × | 1 | × | 1 | |
wifi | × | 1 | × | × | × | |
special | LCD display | 2.4寸 | × | × | × | |
Protocol customized | √ | √ | × | √ | × | |
Zero sequence transformer 30A | × | × | × | √ | × | |
Built-in transformer | 100A | × | 100A | × | 63A | |
USB interface | × | √ | × | × | √ |